#!/bin/sh
set -eux

cleanup() {
    echo ""
    if [ "${FAIL}" = "1" ]; then
        echo "Test failed"
        exit 1
    fi

    echo "Test passed"
    exit 0
}

poolDriverList="${1:-dir btrfs lvm lvm-thin zfs}"
FAIL=1
trap cleanup EXIT HUP INT TERM

# Install test dependencies
apt-get remove --purge cloud-init --yes
apt-get install --yes curl zfsutils-linux genisoimage

# Install Incus
curl -sL https://pkgs.zabbly.com/get/incus-daily | sh

waitVMAgent() (
  set +x
  # shellcheck disable=SC3043
  local vmName="$1"
  for i in $(seq 90) # Wait up to 90s.
  do
    if incus info "${vmName}" | grep -qF 127.0.0.1; then
      return 0 # Success.
    fi

    sleep 1
  done

  echo "VM ${vmName} agent not running after ${i}s"
  return 1 # Failed.
)

# Configure Incus
incus network create incusbr0
incus profile device add default eth0 nic network=incusbr0

poolName="vmpool$$"

GiB=1073741823

for poolDriver in $poolDriverList
do
        # FIXME: LVM on Ubuntu is broken due to the Ubuntu kernel having an io_uring regression
        [ "${poolDriver}" = "lvm" ] && continue

        echo "==> Create storage pool using driver ${poolDriver}"
        if [ "${poolDriver}" = "dir" ] || [ "${poolDriver}" = "ceph" ]; then
                incus storage create "${poolName}" "${poolDriver}"
        elif [ "${poolDriver}" = "lvm" ]; then
                incus storage create "${poolName}" "${poolDriver}" size=60GiB lvm.use_thinpool=false
        elif [ "${poolDriver}" = "lvm-thin" ]; then
                incus storage create "${poolName}" lvm size=20GiB
        else
                incus storage create "${poolName}" "${poolDriver}" size=20GiB
        fi

        echo "==> Create VM and boot"
        incus init images:ubuntu/22.04/cloud v1 --vm -s "${poolName}"
        incus start v1
        waitVMAgent v1
        incus info v1

        echo "==> Check /dev/disk/by-id"
        incus exec v1 -- test -e /dev/disk/by-id/scsi-0QEMU_QEMU_HARDDISK_incus_root
        incus exec v1 -- test -e /dev/disk/by-id/scsi-0QEMU_QEMU_HARDDISK_incus_root-part1
        incus exec v1 -- test -e /dev/disk/by-id/scsi-0QEMU_QEMU_HARDDISK_incus_root-part2

        echo "==> Check config drive is readonly"
        # Check 9p config drive share is exported readonly.
        incus exec v1 -- mount -t 9p config /srv
        ! incus exec v1 -- touch /srv/incus-test || false
        incus exec v1 -- umount /srv

        echo "==> Checking VM root disk size is 10GiB"
        [ $(($(incus exec v1 -- blockdev --getsize64 /dev/sda) / GiB)) -eq "10" ]

        echo "foo" | incus exec v1 -- tee /root/foo.txt
        incus exec v1 -- sync
        incus snapshot create v1

        echo "==> Checking restore VM snapshot"
        incus snapshot restore v1 snap0
        waitVMAgent v1
        incus exec v1 -- cat /root/foo.txt | grep -Fx "foo"

        echo "==> Checking running copied VM snapshot"
        incus copy v1/snap0 v2
        incus start v2
        waitVMAgent v2
        incus exec v2 -- cat /root/foo.txt | grep -Fx "foo"

        echo "==> Checking VM snapshot copy root disk size is 10GiB"
        [ $(($(incus exec v2 -- blockdev --getsize64 /dev/sda) / GiB)) -eq "10" ]
        incus delete -f v2
        incus snapshot delete v1 snap0

        echo "==> Check QEMU crash behavior and recovery"
        incus exec v1 -- fsfreeze --freeze /
        uuid=$(incus config get v1 volatile.uuid)
        pgrep -af "${uuid}"
        rm /run/incus/v1/qemu.monitor
        systemctl restart incus
        sleep 5
        incus ls v1 | grep ERROR
        ! incus stop v1 || false
        ! incus start v1 || false
        pgrep -af "${uuid}"
        incus stop v1 -f
        ! pgrep -af "${uuid}" || false
        incus start v1
        waitVMAgent v1

        echo "==> Testing VM non-optimized export/import (while running to check config.mount is excluded)"
        incus exec v1 -- fsfreeze --freeze /
        incus export v1 "/tmp/incus-test-${poolName}.tar.gz"
        incus delete -f v1
        incus import "/tmp/incus-test-${poolName}.tar.gz"
        rm "/tmp/incus-test-${poolName}.tar.gz"
        incus start v1
        waitVMAgent v1

        echo "==> Testing VM optimized export/import (while running to check config.mount is excluded)"
        incus exec v1 -- fsfreeze --freeze /
        incus export v1 "/tmp/incus-test-${poolName}-optimized.tar.gz" --optimized-storage
        incus delete -f v1
        incus import "/tmp/incus-test-${poolName}-optimized.tar.gz"
        rm "/tmp/incus-test-${poolName}-optimized.tar.gz"
        incus start v1
        waitVMAgent v1

        echo "==> Increasing VM root disk size for next boot"
        incus config device set v1 root size=11GiB
        incus config get v1 volatile.root.apply_quota | grep true
        incus stop -f v1
        incus start v1
        waitVMAgent v1

        echo "==> Checking VM root disk size is 11GiB"
        [ $(($(incus exec v1 -- blockdev --getsize64 /dev/sda) / GiB)) -eq "11" ]

        echo "==> Check VM shrink is blocked"
        ! incus config device set v1 root size=10GiB || false

        echo "==> Checking additional disk device support"
        incus stop -f v1

        # Create directory with a file for directory disk tests.
        mkdir "/tmp/incus-test-${poolName}"
        touch "/tmp/incus-test-${poolName}/incus-test"

        # Create empty block file for block disk tests.
        truncate -s 5m "/tmp/incus-test-${poolName}/incus-test-block"

        # Add disks
        incus config device add v1 dir1rw disk source="/tmp/incus-test-${poolName}" path="/srv/rw"
        incus config device add v1 dir1ro disk source="/tmp/incus-test-${poolName}" path="/srv/ro" readonly=true
        incus config device add v1 block1ro disk source="/tmp/incus-test-${poolName}/incus-test-block" readonly=true
        incus config device add v1 block1rw disk source="/tmp/incus-test-${poolName}/incus-test-block"
        incus start v1
        waitVMAgent v1

        echo "==> Testing VM incus-agent drive mounts"
        # Check there is only 1 mount for each directory disk and that it is mounted with the appropriate options.
        incus exec v1 -- mount | grep '/srv/rw type' -c | grep 1
        incus exec v1 -- mount | grep '/srv/ro type' -c | grep 1

        # RW disks should use virtio-fs when used with the snap.
        incus exec v1 -- mount | grep 'incus_dir1rw on /srv/rw type virtiofs (rw,relatime)'

        # RO disks should use virtio-fs when used with the snap but be mounted readonly.
        incus exec v1 -- mount | grep 'incus_dir1ro on /srv/ro type virtiofs (ro,relatime)'

        # Check UID/GID are correct.
        incus exec v1 -- stat -c '%u:%g' /srv/rw | grep '0:0'
        incus exec v1 -- stat -c '%u:%g' /srv/ro | grep '0:0'

        # Remount the readonly disk as rw inside VM and check that the disk is still readonly at the Incus layer.
        incus exec v1 -- mount -oremount,rw /srv/ro
        incus exec v1 -- mount | grep 'incus_dir1ro on /srv/ro type virtiofs (rw,relatime)'
        ! incus exec v1 -- touch /srv/ro/incus-test-ro || false
        ! incus exec v1 -- mkdir /srv/ro/incus-test-ro || false
        ! incus exec v1 -- rm /srv/ro/incus-test.txt || false
        ! incus exec v1 -- chmod 777 /srv/ro || false

        ## Mount the readonly disk as rw inside VM using 9p and check the disk is still readonly at the Incus layer.
        incus exec v1 -- mkdir /srv/ro9p
        incus exec v1 -- mount -t 9p incus_dir1ro /srv/ro9p
        incus exec v1 -- mount | grep 'incus_dir1ro on /srv/ro9p type 9p (rw,relatime,sync,dirsync,access=client,trans=virtio)'
        ! incus exec v1 -- touch /srv/ro9p/incus-test-ro || false
        ! incus exec v1 -- mkdir /srv/ro9p/incus-test-ro || false
        ! incus exec v1 -- rm /srv/ro9p/incus-test.txt || false
        ! incus exec v1 -- chmod 777 /srv/ro9p || false

        # Check writable disk is writable.
        incus exec v1 -- touch /srv/rw/incus-test-rw
        stat -c '%u:%g' "/tmp/incus-test-${poolName}/incus-test-rw" | grep "0:0"
        incus exec v1 -- rm /srv/rw/incus-test-rw
        incus exec v1 -- rm /srv/rw/incus-test

        # Check block disks are available.
        incus exec v1 -- stat -c "%F" /dev/sdb | grep "block special file"
        incus exec v1 -- stat -c "%F" /dev/sdc | grep "block special file"

        # Check the rw driver accepts writes and the ro does not.
        ! incus exec v1 -- dd if=/dev/urandom of=/dev/sdb bs=512 count=2 || false
        incus exec v1 -- dd if=/dev/urandom of=/dev/sdc bs=512 count=2

        # Remove temporary directory (should now be empty aside from block file).
        echo "==> Stopping VM"
        incus stop -f v1
        rm "/tmp/incus-test-${poolName}/incus-test-block"
        rmdir "/tmp/incus-test-${poolName}"

        echo "==> Deleting VM"
        incus delete -f v1

        # Create directory with a file for directory disk tests.
        mkdir "/tmp/incus-test-${poolName}"

        # Create empty block file for block disk tests.
        truncate -s 5m "/tmp/incus-test-${poolName}/incus-test-block"

        echo "==> Checking disk device hotplug support"
        incus launch images:ubuntu/22.04/cloud v1 --vm -s "${poolName}"
        waitVMAgent v1

        # Hotplug disks
        incus storage volume create "${poolName}" vol1 --type=block size=10MB
        incus storage volume attach "${poolName}" vol1 v1
        sleep 3
        incus exec v1 -- stat -c "%F" /dev/sdb | grep "block special file"
        incus storage volume detach "${poolName}" vol1 v1
        sleep 3
        ! incus exec v1 -- stat -c "%F" /dev/sdb || false
        incus storage volume delete "${poolName}" vol1

        incus config device add v1 block1 disk source="/tmp/incus-test-${poolName}/incus-test-block" readonly=true
        sleep 5
        [ "$(incus exec v1 -- cat /sys/block/sdb/ro)" -eq 1 ]
        incus config device set v1 block1 readonly=false
        sleep 5
        [ "$(incus exec v1 -- cat /sys/block/sdb/ro)" -eq 0 ]

        # Hotplugging directories is not allowed and will fail
        ! incus config device add v1 dir1 disk source="/tmp/incus-test-${poolName}" || false

        # Hot plug cloud-init:config ISO.
        incus config device add v1 cloudinit disk source=cloud-init:config
        sleep 3
        incus exec v1 -- mount -t iso9660 -o ro /dev/sr0 /mnt
        incus exec v1 -- umount /dev/sr0
        incus config device remove v1 cloudinit
        ! incus exec v1 -- stat /dev/sr0 || false

        # Remove temporary directory.
        echo "==> Stopping VM"
        incus stop -f v1
        rm "/tmp/incus-test-${poolName}/incus-test-block"
        rmdir "/tmp/incus-test-${poolName}"

        echo "==> Deleting VM"
        incus delete -f v1

        echo "==> Change volume.size on pool and create VM"
        incus storage set "${poolName}" volume.size 6GiB
        incus init images:ubuntu/22.04/cloud v1 --vm -s "${poolName}"
        incus start v1
        waitVMAgent v1
        incus info v1

        echo "==> Checking VM root disk size is 6GiB"
        [ $(($(incus exec v1 -- blockdev --getsize64 /dev/sda) / GiB)) -eq "6" ]

        echo "==> Deleting VM and reset pool volume.size"
        incus delete -f v1
        incus storage unset "${poolName}" volume.size

        if [ "${poolDriver}" = "lvm" ]; then
                echo "==> Change volume.block.filesystem on pool and create VM"
                incus storage set "${poolName}" volume.block.filesystem xfs
                incus init images:ubuntu/22.04/cloud v1 --vm -s "${poolName}"
                incus start v1
                waitVMAgent v1
                incus info v1

                echo "==> Checking VM config disk filesyste is XFS"
                stat -f -c %T /var/lib/incus/virtual-machines/v1 | grep xfs

                echo "==> Deleting VM"
                incus delete -f v1
                incus storage unset "${poolName}" volume.block.filesystem
        fi

        echo "==> Create VM from profile with small disk size"
        incus profile copy default vmsmall
        incus profile device add vmsmall root disk pool="${poolName}" path=/ size=7GiB
        incus init images:ubuntu/22.04/cloud v1 --vm -p vmsmall
        incus start v1
        waitVMAgent v1
        incus info v1

        echo "==> Checking VM root disk size is 7GiB"
        [ $(($(incus exec v1 -- blockdev --getsize64 /dev/sda) / GiB)) -eq "7" ]
        incus stop -f v1

        echo "==> Copy to different storage pool with same driver and check size"
        if [ "${poolDriver}" = "dir" ] || [ "${poolDriver}" = "ceph" ]; then
                incus storage create "${poolName}2" "${poolDriver}"
        elif [ "${poolDriver}" = "lvm" ]; then
                incus storage create "${poolName}2" "${poolDriver}" size=40GiB lvm.use_thinpool=false
        elif [ "${poolDriver}" = "lvm-thin" ]; then
                incus storage create "${poolName}2" lvm size=20GiB
        else
                incus storage create "${poolName}2" "${poolDriver}" size=20GiB
        fi

        incus copy v1 v2 -s "${poolName}2"
        incus start v2
        waitVMAgent v2
        incus info v2

        echo "==> Checking copied VM root disk size is 7GiB"
        [ $(($(incus exec v2 -- blockdev --getsize64 /dev/sda) / GiB)) -eq "7" ]
        incus delete -f v2
        incus storage delete "${poolName}2"

        echo "==> Copy to different storage pool with different driver and check size"
        dstPoolDriver=zfs # Use ZFS storage pool as that has fixed volumes not files.
        if [ "${poolDriver}" = "zfs" ]; then
                dstPoolDriver=lvm # Use something different when testing ZFS.
        fi

        incus storage create "${poolName}2" "${dstPoolDriver}" size=20GiB
        incus copy v1 v2 -s "${poolName}2"
        incus start v2
        waitVMAgent v2
        incus info v2

        echo "==> Checking copied VM root disk size is 7GiB"
        [ $(($(incus exec v2 -- blockdev --getsize64 /dev/sda) / GiB)) -eq "7" ]
        incus delete -f v2

        echo "==> Grow above default volume size and copy to different storage pool"
        incus config device override v1 root size=11GiB
        incus copy v1 v2 -s "${poolName}2"
        incus start v2
        waitVMAgent v2
        incus info v2

        echo "==> Checking copied VM root disk size is 11GiB"
        [ $(($(incus exec v2 -- blockdev --getsize64 /dev/sda) / GiB)) -eq "11" ]
        incus delete -f v2
        incus storage delete "${poolName}2"

        echo "==> Publishing larger VM"
        incus start v1 # Start to ensure cloud-init grows filesystem before publish.
        waitVMAgent v1
        incus info v1
        incus stop -f v1
        incus publish v1 --alias vmbig
        incus delete -f v1
        incus storage set "${poolName}" volume.size 9GiB

        echo "==> Check VM create fails when image larger than volume.size"
        ! incus init vmbig v1 --vm -s "${poolName}" || false

        echo "==> Check VM create succeeds when no volume.size set"
        incus storage unset "${poolName}" volume.size
        incus init vmbig v1 --vm -s "${poolName}"
        incus start v1
        waitVMAgent v1
        incus info v1

        echo "==> Checking new VM root disk size is 11GiB"
        [ $(($(incus exec v1 -- blockdev --getsize64 /dev/sda) / GiB)) -eq "11" ]

        echo "===> Renaming VM"
        incus stop -f v1
        incus rename v1 v1renamed

        echo "==> Deleting VM, vmbig image and vmsmall profile"
        incus delete -f v1renamed
        incus image delete vmbig
        incus profile delete vmsmall

        echo "==> Checking VM Generation UUID with QEMU"
        incus init images:ubuntu/22.04/cloud v1 --vm -s "${poolName}"
        incus start v1
        waitVMAgent v1
        incus info v1

        # Check that the volatile.uuid.generation setting is applied to the QEMU process.
        vmGenID=$(incus config get v1 volatile.uuid.generation)
        qemuGenID=$(awk '/driver = "vmgenid"/,/guid = / {print $3}' /run/incus/v1/qemu.conf | sed -n 's/"\([0-9a-fA-F]\{8\}-[0-9a-fA-F]\{4\}-[0-9a-fA-F]\{4\}-[0-9a-fA-F]\{4\}-[0-9a-fA-F]\{12\}\)"/\1/p')
        if [ "${vmGenID}" != "${qemuGenID}" ]; then
                echo "==> VM Generation ID in Incus config does not match VM Generation ID in QEMU process"
                false
        fi

        incus delete -f v1

        echo "==> Deleting storage pool"
        incus storage delete "${poolName}"
done

echo "==> Delete network"
incus profile device remove default eth0
incus network delete incusbr0

FAIL=0